Velmayam Industries

Transformer oil supplier in Chennai

Velmayam Industries supplies transformer oil to factories in Chennai and across Tamil Nadu, against IEC 60296, ASTM D3487, IS 335, BS 148 and DIN 57370. The specification your transformer maker calls for decides the oil: send it with the quantity in litres and we match it. The batch certificate and the MSDS come with the consignment.

Updated

A glass beaker of clear, pale gold oil in front of an out-of-focus transformer with cooling fins.

What to send for a rate

  • The specification

    The standard and the type your transformer maker calls for, from the maker's manual or the old drum label.

  • The quantity

    Litres, or the number of drums you take now.

  • The delivery place

    The pin code of the site, so a delivery date can be quoted.

  • If unsure

    A photograph of the old drum label, or the old invoice.

What moves the rate

Specification
The standard and the type that the transformer maker names decide which oil is quoted.
Quantity
The litres you take, on one order or on a schedule, move the rate per litre.
Pack
The pack the oil is delivered in is part of the rate, so say how you receive it now.
Delivery place
The pin code of the site goes into the quote, so send it with the specification.

Which transformer oil specification

Transformer oil is the insulating oil inside an oil-filled transformer: it insulates the windings and carries heat away from them. Transformer oil is bought against a published standard.

The transformer maker names the standard, and that specification decides. Velmayam Industries supplies transformer oil against the five standards below, and the batch certificate and the MSDS come with the consignment.

Send the specification from the maker's manual or the old drum label and we match it. Anything about the oil already in your transformer, including testing, filtration and adding oil, is for the transformer maker's specification and your electrical engineer to decide.

Which transformer oil specification
StandardPublished by
IS 335Bureau of Indian Standards, India
IEC 60296International Electrotechnical Commission
ASTM D3487ASTM International, United States
BS 148British Standards Institution, United Kingdom
DIN 57370DIN, the German standards institute

How Velmayam trades

  • The grade your OEM specifies

    Send the machine manual page or the old drum label. We match the specification rather than talk you into a house brand.

  • Documentation with the drum

    Batch certificate, MSDS and where it applies the H1 or ISO 21469 registration, supplied with the consignment.

  • Proper GST bill and e-way bill

    Correct rate, e-way bill raised every time, documentation that does not complicate your input tax credit.

  • Delivered on the date committed

    We quote a date once stock is confirmed, not before. If it is going to slip, you hear it from us first.

Questions buyers ask

Who supplies transformer oil in Chennai?

Velmayam Industries supplies transformer oil in Chennai and across Tamil Nadu, against IEC 60296, ASTM D3487, IS 335, BS 148 and DIN 57370. The batch certificate and the MSDS come with the consignment. Send the specification your transformer maker calls for and the quantity in litres on WhatsApp to +91 96776 44604, and a quote comes back within 24 hours.

What is the price of transformer oil per litre?

The price of transformer oil per litre depends on the specification the oil is supplied against, the pack, the quantity and the delivery place. Oils made to different standards or types are different products, so compare rates only for the same specification. Send Velmayam Industries the specification your transformer maker calls for and the litres you need, and a quote comes back within 24 hours.

What is the price of a drum of transformer oil?

The price of a drum of transformer oil follows from the rate per litre for the specification you need and the number of litres in the drum. Tell Velmayam Industries the specification your transformer maker calls for and how many drums or litres you take, and a quote comes back within 24 hours. The batch certificate and the MSDS come with the consignment.

What is the specification of transformer oil?

The specification of transformer oil is the published standard that the transformer maker names for the equipment, such as IS 335 in India or IEC 60296 internationally. Velmayam Industries supplies transformer oil against IEC 60296, ASTM D3487, IS 335, BS 148 and DIN 57370. Send the specification from the maker's manual or the old drum label and we match it.

Which type of transformer oil do I need, type 1 or type 2?

The type of transformer oil you need, Type I or Type II, is the one your transformer maker names for the equipment. In ASTM D3487 the two types differ in oxidation resistance, and Type II is the more oxidation resistant oil. Other standards, IS 335 among them, define their own types, so a type number has meaning only inside its standard: read the standard and the type together. The transformer maker's specification and your electrical engineer decide; send the standard, the type and the quantity, and Velmayam Industries matches them.

Is Velmayam a transformer oil manufacturer?

No, Velmayam Industries is a transformer oil supplier and not a manufacturer. It supplies the oil against the specification your transformer maker calls for, among IEC 60296, ASTM D3487, IS 335, BS 148 and DIN 57370, with the batch certificate and the MSDS in the consignment. You get a proper GST invoice and an e-way bill against every order.

What is the BDV test for transformer oil?

The BDV test for transformer oil measures its breakdown voltage: the voltage at which a sample of the oil no longer insulates and a spark passes between two electrodes. The result is given in kilovolts. Whether and when the oil in a transformer is tested is for the transformer maker's specification and your electrical engineer to decide. Velmayam Industries sends the batch certificate and the MSDS with the consignment.

What is transformer oil used for?

Transformer oil is used to insulate and cool an oil-filled transformer: it surrounds the core and the windings, insulates them and carries heat away. Because the oil is part of the electrical insulation, it is bought against the standard the transformer maker names. Send Velmayam Industries the specification from the maker's manual or the old drum label, with the quantity in litres, for a quote within 24 hours.

Lines this page covers

  • Transformer oilSpecification, litres

Build a requirement slip from the transformer oil range

Company brochurePDF, 1.2 MB

Related pages

Send the item list on WhatsApp

Who you are buying from

Velmayam Industries was incorporated in August 2026. The people running it are not new. Our COO has eight years supplying industrial consumables to manufacturers across Tamil Nadu, including multi-unit textile mills, under a previous business.

Advance payment for first orders; credit terms for approved accounts.

Lead time and minimum order are confirmed with each quote.

Call +91 72004 64908 WhatsApp +91 96776 44604